Fsn rubber concrete jack up system.
Mason fsn floating floor mount.
Fsn4 indicates a 4 floor and housing.
There are thee main varieties of concrete floating floor.
Castings can be modified for floors over 6 thick.
Fsn 3 4 5 6 25 0 3500 12 47 12147 red white 50 60 1675 2350 3500 761 1068 1590 black gray fsn housing height matches floor thickness.
Concrete floating floors comprise of a reinforced concrete layer supported by isolators.
Air gap a floor thickness b.
Plastic sheeting is placed on the sub floor as a breaker layer isolators are placed on the plastic sheeting reinforcing steel or mesh rests on the isolator housings and the concret.
We believe that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
When installed correctly they can last for.
Like icing on a cake transitions are typically the last materials to complete the floating floor project.
Plastic sheeting is placed on the sub floor as a breaker layer isolators are placed on the plastic sheeting reinforcing steel or mesh rests on the isolator housings and the concrete floor is poured.
Mason jack up floor slab system we believe that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
The isolators can be either rubber or spring depending on the nature of the noise or vibration.
Fsn6 a 6 floor and housing etc.
Housing suffix indicates housing height i e.
Our riverbank test data demonstrates that a four inch thick concrete floor floating on neoprene mounts improves the stc by 25 if raised two inches and that the inr goes up by 44.
The fsn system ensures there is no bridging of the two elements due to slurry ingress plastic sheeting is placed on the sub floor as a breaker layer.
This uses the mason jack up system to raise a concrete layer.
Floating floors transitions and trim complement the flooring and provide a safe durable way to create expansion contraction space between areas and lead to other existing floors in the home.
Fsn jack up floating floor isolation mounts it has been proven that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
Plastic sheeting is placed on the sub floor as a breaker layer isolators are placed on the plastic sheeting reinforcing steel or mesh rests on the isolator housings and the concrete.
We believe that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
Vibration isolation technology has moved on to the isolation of entire buildings rather than just building components.